Click For Hindi Website
 
 
ICAR-Indian Grassland and Fodder Research InstituteICAR-Indian Grassland and Fodder Research Institute
(Indian Council of Agricultural Research)
Near Pahuj Dam, Gwalior Road, Jhansi - 284 003 (UP) India
  logo logo
  0510-2730666, 2730158
0510-2730385
  FAX: 0510-2730833
igfri_jhansi@yahoo.co.in
igfri.director@gmail.com
 
Instrument Details
Instrument/Facility Name: Atomic Absorption Spectrometer (AAS)
Make: Varian
Model: AA 240
Specification:
  • Flame type atomic absorption spectrometer
  • PC based with software and accessories
  • Have double beam spectrometers
  • Highly sensitive with less interference
  • Provision for background corrections
The Varian AA 240 AAS is an easy-to-use, but robust equipment with 4 lamp capability. It provides high performance and lower running costs. On normal application, Varian AA 240 system delivers real productivity improvements in flame AA. High productivity means reduced gas, reagent and lamp usage, and better results. Pure gases like C2H2, and N2O/ air are used for production of flames.

Click to View
Working Principles:
This is a technique for analysis of elements in liquids. Metallic elements are determined in both organic and inorganic samples. It is a sensitive technique with standard flame that can determine the concentration of most elements at the parts per million (ppm) level. Through the use of calibration curves, prepared from suitable standards, a high level of accuracy and precision (± 1-3%) is achieved in flame AAS. This allows for compositional as well as traces impurity analysis. Most spectral interferences and matrix effects are overcome by utilizing well-characterized conditions and matrix matching of samples and standards.
Click to View
Applications:
AAS is usually used to determine the concentration of elements such as calcium, magnesium, copper, zinc, iron, manganese, cobalt etc. in different biological (food, feed, fodder, blood and urine) and soil samples.
User Instructions:
Biological and soil samples need to be processed either by dry or wet digestion method, prior to determine the concentrations of elements in samples.
Contact Us:
Contact No: 05102730666
Email Id: igfri.director@gmail.com; director.igfri@icar.gov.in
Atomic Absorption Spectrometer (AAS) Charges:
Procedure Name Industry University National LAB/R&D Remarks
        Fees & charges: • Macro elements (Ca & Mg) - Rs 1000 per sample plus service tax / • Micro elements (Cu, Zn, Fe, Mn, Co etc) – Rs 1500 per sample plus service tax
Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of ""
Letter, DD & Samples send to "Letter & Samples send to "The Director, IGFRI, Jhansi-284003""
     
   
     
 
Copyright © 2015 Indian Grassland and Fodder Research Institute, Jhansi
 
     
 
Developed & Maintained by Transoft Infotech Agra